-40%

Three Phase Power Quality Analyzer Tester with ETCR068B Current Sensor 1000V

$ 1140.48

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: 10369963
  • Country/Region of Manufacture: China
  • Screenshot capacity:: 60
  • Expert mode:: Yes
  • Brand: VTSYIQI
  • Return shipping will be paid by: Buyer
  • Display mode: LCD color screen, 640dots×480dots,
  • Restocking Fee: No
  • Phase Configuration: 3-Phase
  • Communication interface:: USB
  • Number of channels: 4U/4I.
  • Voltage flicker:: Yes
  • Line voltage:: 1.0V~2000V
  • Frequency: 40Hz~70Hz.
  • Harmonic:: Yes, 0 to 50 times
  • Condition: New
  • Current Measurement Range: AC 0.1A~1000A
  • Voltage Measurement Range: 1.0V~1000V

    Description

    ETCR5000 Power Quality Analyzer's basic function:

    Transient capture function
    Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctu-ations, voltage current surge, sag and short supply interruption, temporary overvoltage, impact current and Cur-rent voltage instantaneous distortion. Instruments can store 150 sets of transient waveform at the same time.

    Starting current monitoring
    Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity. Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4 channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and waveform curve of each cycle in 100s.

    Trend chart recording and storing function
    Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms,  Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).

    Alarm function
    Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as: voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distor-tion. You can configure 40 different alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.

    Snapshot function
    Any screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.

    Communication function
    Communicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the transient waveform, trend chart recording, alarm log, screenshots, and display on the computer.

    Setting function
    The user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase curve colors’.
    Choice of type of connection to the net work.
    Configuration of the type of the current sensors and voltage ratios.
    Select Chinese menu or English menu.

    Help menu in Chinese/English
    Every stage of operation can press the "help" key to obtain relevant information.
    Specification Description


    Power Supply: Rechargeable lithium battery pack 9.6V, external charger

    Power consumption: Current consumption 490mA, battery work 8 hours continuously

    Current clamp type: ETCR 068B current clamp: 68mm * 68mm(4PCS), CT size: Ф68mm

    Channel number: 4U/4I

    Line voltage: 1.0V

    2000V

    Phase voltage: 1.0V

    1000V

    Frequency: 40Hz

    70Hz

    Power parameter: W

    VA

    var

    PF

    DPF

    cosφ

    tanφ

    Electrical parameters: Wh

    varh

    Vah

    Harmonic: Yes, 0 to 50 times

    Total harmonic distortion:Yes, 0 to 50 times, each phase

    Expert mode: Yes

    Transient record group: 150 groups

    Voltage flicker: Yes

    Start current mode: Yes, 100 seconds

    Three phase unbalance: Yes

    Record: 300 days (record 20 parameters at the same time, record every 5 seconds, 1 points)

    Alarm:40 different types of parameters, the 12800 group alarm log

    Phasor diagram display: automatic

    Screenshot capacity: 60

    Menu language: Chinese and English

    Communication interface: USB

    Automatic shutdown: The instrument does not shut down automatically when the alarm / trend chart recording / transient capture mode is in progress

    In other test mode, 15 minutes without key operation, prompt automatic shutdown after 1 minutes.

    Test line: Voltage test line 3m, Current clamp 2m

    Operating temperature and humidity: -10
    ℃~
    40

    ;below 80%Rh

    Storage temperature and humidity: -10
    ℃~
    60

    ;below 70%Rh

    Input impedance:Test voltage input impedance: 1MΩ

    Safety regulation: IEC 61010 1000V Cat III / 600V CAT IV

    IEC61010-031

    IEC61326

    Pollution level 2

    Accessory: Host: 1; instrument box: 1; test line: 5 (yellow, green, red, blue, black, 1); Alligator clip: 5; Pen: 5; charger: 1; CD: 1; lithium battery group: 1; 2G memory card: 1;ETCR068B current sensor

    4