-40%

Fluke 345 Single Phase Power Quality Clamp Meter

$ 1000.56

Availability: 100 in stock
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Phase Configuration: Single Phase
  • Maximum Peak Transient Voltage: N/A
  • Voltage Measurement Range: N/A
  • California Prop 65 Warning: N/A
  • Bandwidth: N/A
  • Current Measurement Range: N/A
  • MPN: 345
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Brand: Fluke
  • Condition: Seller refurbished
  • All returns accepted: Returns Accepted

    Description

    ebay template
    The Following Items Are Included:
    Fluke 345 Power Quality Clamp Meter (BC# 40316)
    (2) 1000V Hard Point Test Leads
    (2) Alligator Clips
    AC Adapter/Charger
    USB PC Interface Cable
    User Manual On CD-ROM
    Carrying Case (G)
    BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS!
    This Item Has A Current Calibration!
    Fluke 345 Single Phase Power Quality Clamp Meter
    The Fluke 345 is ideal for measurements on switching loads such as variable frequency drives, electronic lighting and UPS systems
    Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
    Includes Carrying Case & Accessories As Listed Above!
    Working Condition: Excellent
    Calibrated: Factory Calibration
    Condition: Refurbished
    Warranty: 1 YEAR WARRANTY
    Fluke 345 Power Quality Clamp Meter
    The ideal meter for commissioning and troubleshooting modern electrical loads
    With a bright color display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 is ideal for measurements on switching loads such as variable frequency drives, electronic lighting and UPS systems. Additionally, the Hall Effect measurement system makes measurement of dc current possible without the need to break the circuit, and the internal memory enables long-term logging for analysis of trends or intermittent problems.
    Log measured parameters
    All voltage, current, power, and harmonic measurements can be logged for minutes, hours, or months. Measurement averaging periods from 1 second to 15 minutes can be selected depending on the application.
    Measured parameters can be logged into three separate recording memory areas. If longer recordings are required, the three areas may be combined into one. Stored measurements can be recalled and displayed on-screen in normal screen format or downloaded using the Power Log software package.
    Flexible and easy to use
    The 345 measures a wide range of electrical parameters and can be used for many applications in today’s modern electrical environment. Measuring mode is selected by a simple turn of the rotary switch and the large color display presents data in a clear, easy-to-understand way.
    By default the display will show the most common measurements, in very large format. If more detailed views are required they are available with the press of a single key (up to six measurements at once).
    Inrush current
    Diagnose equipment start-ups with the inrush current mode. A current trigger level is set prior to recording. Once the level has been exceeded, the meter will begin capture. Recordings from 3 seconds to 300 seconds may be captured, and up to 1000 inrush events may be stored in the instruments memory.
    Screen captures and data logging
    Any measurement can be stored in memory for later viewing, or downloaded to a PC. Simply press ‘SAVE’ to capture the active screen to memory – up to 50 screen shots can be saved for quick and simple documentation. Additionally, over 150,000 individual measurements can be logged for later review on the display or on a PC using Power Log software.
    Features:
    AC/DC current:
    Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
    Highest safety rating:
    600 V CAT IV rated for use at the service entrance
    Accurate in noisy environments:
    Even with distorted waveforms present on electronic loads with low-pass filter
    Data logging:
    Identify intermittent faults by logging any power parameters for minutes or months, including harmonics
    Verify batteries:
    Direct measurement of dc ripple (%) for battery and dc systems
    Troubleshoot harmonics:
    Analyze and log harmonics digitally or graphically
    Inrush current:
    Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
    Easy to use:
    Easily confirm instrument setup with large backlit color display of waveforms and trends
    3-Phase power:
    Built in capability for balanced loads
    View graphs and generate reports:
    With Power Log software
    Applications:
    Set
    up and troubleshoot variable frequency drives and UPS systems
    Verify correct operation by measuring key parameters
    Harmonics measurements
    Uncover harmonic issues that can damage or disrupt critical equipment
    Inrush capture
    Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
    Load studies
    Verify electrical system capacity before adding loads
    Specifications:
    Display
    Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight
    Power supply
    Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
    Battery life typically
    > 10 hours (backlight on full)
    > 12 hours (backlight reduced)
    Battery Eliminator BE345
    Input: 110 V/230 V, 50/60 Hz
    Output: 15 V dc, 300 mA
    Ambient conditions (For indoor use only)
    Reference conditions
    All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F)
    Operating temperature
    0 °C to 50 °C (32 °F to 122 °F)
    Temperature coefficient of current
    ≤ ± 0.15 % of rdg per °C
    Temperature coefficient of voltage
    ≤ ± 0.15 % of rdg per °C
    Maximum relative humidity
    80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F)
    Maximum operating altitude
    2000 m
    Electrical safety
    Safety IEC 61010-1 600 V CAT IV, double or reinforced insulation, pollution degree 2
    Protection IP40; EN60529
    Maximum safe working voltages
    Current measurement: 600 V ac rms or dc between uninsulated conductor and ground
    Voltage measurement: 600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
    EMC
    Emission
    IEC/EN 61326-1:1997 class B
    Immunity
    IEC/EN 61326-1:1997
    Mechanical
    Dimensions (length x width x depth)
    300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
    Weight including batteries
    820 g/1.8 lb
    Jaw opening
    60 mm
    Jaw capacity
    58 mm diameter
    Cleaning
    The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
    Electrical data
    All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient conditions specifications for temperature coefficients.
    Current measurement
    (dc, dc rms, ac rms)
    Measuring range
    0 to 2000 A dc or 1400 ac rms
    Autorange facility
    40 A/400 A/2000 A
    Resolution
    10 mA in 40 A range
    100 mA in 400 A range
    1 A in 2000 A range
    Accuracy
    DC and dc rms
    I > 10 A: ± 1.5 % rdg ± 5 digits
    I < 10 A: ± 0.2 A
    AVG
    I > 10 A: ± 3 % rdg ± 5 digits
    I < 10 A: ± 0.5 A
    Pk
    I > 10 A: ± 5 % rdg ± 5 digits
    I < 10 A: ± 0.5 A
    AHr
    I > 10 A: ± 2 % rdg ± 5 digits
    I < 10 A: ± 0.5 AHr
    CF (Crest Factor)
    1.1 ≤ CF < 3: ± 3 % rdg ± 5 digits
    3 ≤ CF < 5: ± 5 % rdg ± 5 digits
    Resolution: 0.01
    RPL (Ripple)
    2 % ≤ RPL < 100 %: ± 3 % rdg ± 5 digits
    100 % ≤ RPL < 600 %: ± 5 % rdg ± 5 digits
    Resolution: 0.1 %
    Idc > 5 A, Iac > 2 A
    Voltage measurement
    (dc, dc rms, ac rms)
    Measuring range
    0 to 825 V dc or ac rms
    Autorange facility
    4 V/40 V/400 V/750 V
    Resolution
    1 mV in 4 V range
    10 mV in 40 V range
    100 mV in 400 V range
    1 V in 750 V range
    Accuracy
    DC and dc rms
    V > 1 V: ± 1 % rdg ± 5 digits
    V < 1 V: ± 0.02 V
    AVG
    V > 1 V: ± 3 % rdg ± 5 digits
    V < 1 V: 0.03 V
    Pk
    V > 1 V: ± 5 % rdg ± 5 digits
    V < 1 V: ± 0.03 V
    CF (Crest Factor)
    1.1 ≤ CF < 3: ± 3 % rdg ± 5 digits
    3 ≤ CF < 5: ± 5 % rdg ± 5 digits
    Resolution: 0.01
    RPL (Ripple)
    2 % ≤ RPL < 100 %: ± 3 % rdg ± 5 digits
    100 % ≤ RPL < 600 %: ± 5 % rdg ± 5 digits
    Resolution: 0.1 %
    Vdc > 0.5 V, Vac > 0.2 V
    Harmonics
    THD (Total Harmonic Distortion)
    1 % ≤ THD < 100 %: ± 3 % rdg ± 5 digits
    100 % ≤ THD < 600 %: ± 5 % rdg ± 5 digits
    Resolution: 0.1 %
    DF (Distortion Factor)
    1 % ≤ DF < 100 %: ± 3 % rdg ± 5 digits
    Resolution: 0.1 %
    H02 ≤ Vharm < H13: ± 5 % rdg ± 2 digits
    H13 ≤ Vharm ≤ H30: ± 10 % rdg ± 2 digits
    Watts measurement (single- and three-phase)
    (dc, dc rms, ac rms)
    Measuring range
    0 to 1650 kW dc or 1200 kW ac
    Autoranging facility
    4 kW, 40 kW, 400 kW, 1650 kW ac
    Resolution
    1 W in 4 kW
    10 W in 40 kW
    100 W in 400 kW
    1 kW in 1200 kW
    Accuracy
    2.5 % rdg ± 5 digits
    W1Ø < 2 kW ± 0.08 kW
    W3Ø < 4 kW ± 0.25 kW
    VA measurement (single- and three-phase)
    (dc, dc rms, ac rms)
    Measuring range
    0 to 1650 kVA dc or 1200 kVA ac
    Autorange facility
    4 kVA, 40 kVA, 400 kVA, 1650 kVA
    Resolution
    1 VA in 4 kVA
    10 VA in 40 kVA
    100 VA in 400 kVA
    1 kVA in 1200 kVA
    Accuracy
    VA > 2 kVA
    2.5 % rdg ± 5 digits
    VA < 2 kVA
    ± 0.08 kVA
    VAR measurement (single- and three-phase)
    Measuring range
    0 to 1250 kVAR
    Autorange facility
    4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR
    Resolution
    1 VAR in 4 kVAR
    10 VAR in 40 kVAR
    100 VAR in 400 kVAR
    1 kVAR in 1200 kVAR
    Accuracy
    VAR > 4 kVAR
    ± 2.5 % rdg ± 5 digits
    VAR < 4 kVAR
    ± 0.25 kVAR
    Power factor range
    0.3 < PF < 0.99
    Power factor (single- and three-phase)
    Measuring range
    0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive)
    Resolution
    0.001
    Accuracy
    ± 3°
    Frequency range
    15 Hz to 1 kHz
    Displacement power factor
    Measuring range
    0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0° to 72.5° inductive)
    Resolution
    0.001
    Accuracy
    ± 3°
    Frequency range
    15 Hz to 22 Hz and 45 Hz to 65 Hz
    Kilowatt hour (kWHr)
    Measuring range
    40,000 kWHr
    Autorange facility
    1 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr
    Resolution
    1 WHr in 4 kWHr
    10 WHr in 40 kWHr
    100 WHr in 400 kWHr
    1 kWHr in 4,000 kWHr
    10 kWHr in 40,000 kWHr
    Accuracy
    kWHr > 2 kWHr
    ± 3 % ± 5 digits
    kWHr < 2 kWHr
    ± 0.08 kWHr
    All Watts /VA /VAR /PF measurements
    Frequency range
    DC and 15 Hz to 1 kHz
    Current range
    10 A to 1400 A rms
    Voltage range
    1 V to 825 V rms
    Maximum input
    825 V rms/1400 A rms
    Maximum overload
    1000 V rms/10,000 A
    Frequency measurement
    (from current or voltage sources)
    Measuring range
    15 Hz to 1 kHz
    Resolution
    0.1 Hz
    Accuracy
    15 to 22 Hz ± 0.5 % rdg
    40 Hz to 70 Hz ± 0.5 % rdg
    15 Hz to 1000 Hz ± 1% rdg
    Current range
    10 A to 1400 A rms
    Voltage range
    1 V to 825 V rms
    Scope function
    Current measurement
    Ranges
    10 A/20 A/40 A/100 A/200 A/400 A/1000 A/2000 A
    Resolution
    1 A in 40 A
    10 A in 400 A
    50 A in 2000 A
    Accuracy
    ± 3 % rdg ± 1 pixel
    Maximum overload
    10,000 A
    Voltage measurement
    Ranges
    4 V/10 V/20 V/40 V/100 V/200 V/400 V/1000 V
    Resolution
    100 mV in 4 V
    1 V in 40 V
    10 V in 400
    V 31.25 V in 1000 V
    Accuracy
    ± 2 % rdg ± 1 pixel
    Maximum overload
    1000 V rms
    Frequency range
    DC and 15 Hz to 600 Hz
    Time base
    2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
    Refresh rate
    0.5 seconds
    Maximum sampling rate
    15.625 kHz
    Inrush current function
    Ranges
    40 A, 400 A, and 2000 A
    Resolution
    10 mA in 40 A range
    100 mA in 400 A range
    1 A in 2000 A range
    Accuracy
    I > 10 A
    ± 5 % rdg ± 1 pixel
    I < 10 A
    ± 0.5 A
    Maximum overload
    Maximum overload 10,000 A or rms x frequency < 400,000
    Capture time
    1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
    Maximum sampling rate
    15.625 kHz
    Interface
    USB Interface to a PC
    Power Log software for download, analysis, and reporting
    345 Upgrade Utility for installing a new firmware version
    Logging Memory
    Logging areas
    Three areas that can be used individually or combined into one large area
    Averaging periods
    1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom
    Logging times
    Volts and current mode
    Average time
    Logging time (1 area)
    Logging time (3 areas)
    1 s
    1 h 49 m
    5 h 12 m
    2 s
    3 h 38 m
    10 h 24 m
    5 s
    9 h 06 m
    1 d 2 h 00 m
    10 s
    18 h 12 m
    2 d 04 h 00 m
    30 s
    2 d 06 h 36 m
    6 d 12 h 01 m
    1 min
    4 d 13 h 12 m
    13 d 00 h 03 m
    5 min
    22 d 18 h 00 m
    65 d 00 h 15 m
    10 min
    45 d 12 h 00 m
    130 d 00 h 30 m
    15 min
    68 d 06 h 00 m
    195 d 00 h 45 m
    V & A harmonics mode
    Average time
    Logging time (1 area)
    Logging time (3 areas)
    1 s
    0 h 34 m
    1 h 38 m
    2 s
    1 h 08 m
    3 h 16 m
    5 s
    2 h 52 m
    08 h 11 m
    10 s
    5 h 44 m
    16 h 23 m
    30 s
    17 h 13 m
    2 d 01 h 11 m
    1 min
    1 d 10 h 26 m
    4 d 02 h 23 m
    5 min
    7 d 04 h 10 m
    20 d 11 h 25 m
    10 min
    14 d 08 h 20 m
    81 d 0 h 50 m
    15 min
    21 d 12 h 30 m
    121 d 13 h 15 m
    single- and three-phase power mode
    Average Time
    Logging Time (1 area)
    Logging Time (3 areas)
    1 s
    1 h 40 m
    4 h 47 m
    2 s
    3 h 21 m
    9 h 34 m
    5 s
    8 h 22 m
    23 h 57 m
    10 s
    16 h 45 m
    1 d 23 h 54 m
    30 s
    2 d 02 h 17 m
    5 d 23 h 42 m
    1 min
    4 d 04 h 35 m
    11 d 23 h 25 m
    5 min
    20 d 22 h 55 m
    59 d 21 h 05 m
    10 min
    41 d 21 h 50 m
    119 d 18 h 10 m
    15 min
    62 d 20 h 45 m
    179 d 15 h 15 m
    For full Fluke 345 product specifications, please click here:
    Fluke 345
    Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
    Ebay Test Equipment Store
    . All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
    contact us
    for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
    Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
    We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
    We Ship World Wide!
    We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
    Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
    We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
    We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
    Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
    Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
    A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
    Thank you
    ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
    Sell Smarter with
    Kyozou
    .
    Inventory and Ecommerce Management